Turbidity
โพสต์เมื่อ : 26 ม.ค 2566 เวลา 7:34 น.
บทความrefractometer2z-z1635050051083.pdf บทความrefractometer2z-z1665397887981.pdfMD 200 Photometer
Precise results using high-quality interference filters
Versatile Bench Scales Meet
Highlights:
Designed to meet the latest technical requirements, the MD 200 photometer can be used in practically every area of water analysis.
The high-precision optics with its top-quality interference filters uses long-term stable LEDs as light-source. Because there are no moving parts, the entire measurement device requires absolutely no maintenance.
Precise and reproducible analysis results are obtained in a short time. The units impress with their user-friendliness, ergonomic design, compact dimensions and easy handling.
The tests are conducted using either Lovibond®tablet reagents with long-term stability and a guaranteed minimum 5 or 10 year shelf life or using liquid reagents.
Precise results using high-quality interference filters
Versatile Bench Scales Meet
Highlights:
- • Scroll Memory
• Automatic Switch-Off
• Real-Time-Clock and Date
• Calibration mode indicator
• Backlit Display
• Storage Function
• One Time Zero (OTZ)
• Waterproof*)
Designed to meet the latest technical requirements, the MD 200 photometer can be used in practically every area of water analysis.
The high-precision optics with its top-quality interference filters uses long-term stable LEDs as light-source. Because there are no moving parts, the entire measurement device requires absolutely no maintenance.
Precise and reproducible analysis results are obtained in a short time. The units impress with their user-friendliness, ergonomic design, compact dimensions and easy handling.
The tests are conducted using either Lovibond®tablet reagents with long-term stability and a guaranteed minimum 5 or 10 year shelf life or using liquid reagents.
บทความrefractometer3z-z616789654526.pdfบทความrefractometer3z-z1764264332003.pdfThermoreactor R 125
For the Tube test digestion of:
The required temperatures and reaction time can be selected by using the membrane keypad of the reactor RD 125. The unit works at three different temperatures (100 / 120 / 150 °C) and three pre-set reaction times 30 / 60 / 120 minutes). When digestion is complete, the reactor automatically switches off and gives a corresponding LED indication with short beep alarm. The RD 125 reactor is fitted with 24 holes for 16 mm diameter vials. With the voltage switch on the back 230 V and 115 V are selectable.
For the Tube test digestion of:
- • COD (150°C)
• TOC (120°C)
• Total Chromium (100°C)
• Total Nitrogen (100°C)
• Total Phosphate (100°C)
The required temperatures and reaction time can be selected by using the membrane keypad of the reactor RD 125. The unit works at three different temperatures (100 / 120 / 150 °C) and three pre-set reaction times 30 / 60 / 120 minutes). When digestion is complete, the reactor automatically switches off and gives a corresponding LED indication with short beep alarm. The RD 125 reactor is fitted with 24 holes for 16 mm diameter vials. With the voltage switch on the back 230 V and 115 V are selectable.